Error description
DESCRIPTION : When CATIA opens a specific IGES file (with MM dimensions), CATIA interprets the file as a file with Inch dimensions: all the dimensions are multiplied by 25.4 STEP BY STEP SCENARIO : 1. Open with a text editor the IGES file, check that there is the following in the file header :2,2HMM That means that the IGES file is in millimeters 2. Open the IGES file with CATIA 3. Check that the dimensions are multiplied by 25.4 and that in the report, CATIA interprets the file as a INCH dimensionned file.
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
THIS APAR IS CONSIDERED AS A SUGGESTION FOR IMPROVEMENT FOR CATIA. REASON: THE IGES FILE WAS NOT COMPLIANT TO THE IGES STANDARD : THE FIELD 3 AND 12 CONTAIN FORBIDDEN ASCII CHARACTER ACCORDING TO THE STANDARD. EXAMPLE FOR FIELD 3 LINE 1 : 6H00XYZ WHERE THE '0' ARE BINARIES '0' FORBIDDEN BY THE STANDARD THE CUSTOMER SHOULD CONTACT EUCLID TO FIX THE BUG MOREOVER, WE ARE PLANNING ON IMPROVING THE IGES PARSER IN ORDER TO DETECT THIS KIND OF ERROR AND INFORM THE USER OF THE PROBLEM THIS IMPROVEMENT WILL BE DEVELOPPED FOR A FURTHER RELEASE.
APAR Information
APAR number
HC88342
Reported component name
CATIA V5 NT_INT
Reported component ID
569151000
Reported release
506
Status
CLOSED SUG
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2001-12-05
Closed date
2002-01-30
Last modified date
2002-01-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"506","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
30 January 2002