IBM Support

HC86869: ASSEMBLY - INSTANCE NAME SHOULD NOT BE DISPLAYED IN SCENE TRE E STRUCTURE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • .
    Instance name should not be displayed in scene tree
    structure for root
    assemblies.
    .
    Scenario;
    1) Start Catia V5R6 SP3
    2) Open the product '4587567,EC0001 ,R0.CATProduct'
    3) Double click in the scene 'Exploded'
    == The first branch in the tree is the product with the Part
    Number
    4587567. In parenthesis (My Assembly) is the initial name of
    the
    assembly before being renamed. But this name does mean
    anything and is
    not related to a property of the product.
    Nothing should be displayed in parenthesis.
    
    ABSTRACT: ASSEMBLY - Instance name should not be displayed
    in scene tree
    
    
    Hello Bert,
       Here is the result of our investigations. First of all,
    the name of
    an object is always composed of two elements:
              - The Part Number
              - The Instance Name (between parenthesis)
    So this name means something '''' You can point on the same
    instance
    two  or X times under a same product. So the Part Number
    will be
    diferent but not the Instance Name. Now this is true that
    you don't
    need to have those informations for the root product. This
    screen
    apearance is customizable in
    TOOLS/OPTIONS/INFRASTRUCTURE/PRODUCT
    STRUCTURE/NODES CUSTOMIZATION, modifying Node Display to
    "customized
    display".
    Thanks for your comprehension.
    Best Regards, Pierre.
    
    
    
    Dassault, please see and review Alains response that
    follows.
    Pierre, Thank you for your explanation. I understand that
    the Node
    Display can be customized. However, your proposal does not
    solve the
    problem.
    1- An instance name on a root assembly does not have any
    meaning in
    general and should never be displayed whatever is the Node
    Display
    customization (ref: PMR  06960, APAR HC76346 already been
    open and fixed
    by Dassault). Actually, the product does not have an
    instance name
    the scene. An instance name should not appear on a root
    product within
    a scene.
    2 - On the particular example provided with the PMR, the
    instance name
    (My Assembly) displayed in the scene tree is not link to a
    Part Number
     or an Instance Name! Why is the string 'My Assembly'
    displayed? Where
    is this string coming from?
    Please open a new APAR to address this problem.
    

Local fix

Problem summary

  •  INCIDENT DIAGNOSIS:
      ASSEMBLY - INSTANCE NAME SHOULD NOT BE DISPLAYED IN SCENE
    TREE STRUCTURE
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON
      CATIA VERSION 5 RELEASE 9 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R8SP2 and V5R7SP7
    
     TECHNICAL EXPLANATION FOR THE CORRECTION:
    The instance name of the root product isn't displayed anymore
    in a scene.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC86869

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    506

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2001-10-29

  • Closed date

    2002-02-28

  • Last modified date

    2003-06-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    FILE
    

Fix information

  • Fixed component name

    CATIA V5 NT_INT

  • Fixed component ID

    569151000

Applicable component levels

  • R506 PSN

       UP

  • R507 PSN

       UP

  • R508 PSN SP50802

       UP02/03/25 N 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"506","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: