IBM Support

HC76092: UPDATE ERROR ON A CHAMFER PRIMITIVE AFTER A V4 SOLID IS PASTED AS SPECS INTO A V5 PART

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Start a V5 session:
    . File.Open the associated model
    . Edit.Copy *MASTER
    . File.New Part
    . Edit.Paste Special as Specs
      > OK
    . Update
      > a popup window is displayed with the message:
        Chamfer.56 ($CHAM83):
        topological operators - internal error
    
    None
    

Local fix

Problem summary

  • Update problem on Chamfer.56 primitive after the V4 geometry
    was copied as specifications into the V5 part.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON
      CATIA VERSION 5 RELEASE 9 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R8SP02.
                                                                   .
    WARNING: the delivered correction is only partial.
                                                                   .
    The initial error was about Chamfer.56: the problem existed
    because a naming error on a face.
    The correction of this problem shows another error on Edge
    Fillet.14: one of the 2 supporting faces do not exist anymore
    when trying to create the edge fillet.
    Using the following exports:
       BREP_MAPPIMG_ON=1
       UPDATE_ON = 1
    the situation is better, but not fully satisfactory.
                                                                   .
    A part of the closure is therefore PER (it provides a protection
    against a core dump possibility).
    The remaining issue corresponds to a specific configuration for
    which the current closure is SUG.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC76092

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    505

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2001-01-30

  • Closed date

    2002-02-20

  • Last modified date

    2003-06-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    FILE
    

Fix information

  • Fixed component name

    CATIA V5 NT_INT

  • Fixed component ID

    569151000

Applicable component levels

  • R507 PSN

       UP

  • R508 PSN SP50802

       UP02/03/25 N 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"505","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
10 June 2003