  • Closed as program error.

Error description

  • When exporting a Board the user can choose what kind of file to
    be created:  IDF 3.0, IDF 2.0(Allegro), IDF 2.0 (MG) or DXF.
    However, whatever the option selected, you get the same result:
    and IDF 2.0 file with name ending with extension"idf".
    What we are requesting is to make the option work the way it
    says it should.
    For instance when IDF 2.0 (Allegro) is selected, and IDF 2.0
    file with the name ending with extension "BDF" should be
    created.  When DXF is selected a DXF file should be created.
    

Local fix

Problem summary

  • In CBD, no management of bdf and brd extension is offered,
    only idf is proposed.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON
      CATIA VERSION 5 RELEASE 4 GA level .
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R3SP6
    
    The issue is solved.
    During the export, if you select :
    - IDF 2.0, the system will save with ext. *.idf
    - IDF 2.0 (MG), the system will save with ext. *.brd
    - IDF 2.0 (Allegro), the system will save with ext. *.bdf
    .
    Remark : NO dxf extension is proposed as this format is not
    considered as a CBD dedicated one.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC62053

  • Reported component name

    CATIA V5 NT_INT

  • Reported component ID

    569151000

  • Reported release

    502

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2000-03-13

  • Closed date

    2000-03-23

  • Last modified date

    2000-08-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    FILE
    

Fix information

  • Fixed component name

    CATIA V5 NT_INT

  • Fixed component ID

    569151000

Applicable component levels

  • R002 PSN

       UP

  • R102 PSN

       UP

  • R202 PSN

       UP

  • R302 PSN

       UP

  • R502 PSN

       UP

  • R003 PSN SP00306

       UP00/04/10 N 1000

  • R103 PSN SP10306

       UP00/04/10 N 1000

  • R2303 SN SP203503

       P00/04/10 I 1000

  • R303 PSN SP30306

       UP00/04/10 N 1000

  • R503 PSN SP50306

       UP00/04/10 N 1000