Error description
When using * $$ PUN MEM=... for directing Punch Output to VSE/AF Sublibrary Member, VSE/POWER may terminate abnormally indicated by message 1Q2CI for an Execution RDR task. PSW will point to offset x255E in phase IPW$$XJ.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users which are using * $$ PUN MEM=... * * redirection. * **************************************************************** * PROBLEM DESCRIPTION: VSE/POWER can be abnormally terminated * * if * $$ SLI statement is using right * * after * $$ PUN MEM=... statement. * * Recommendation: (optional field) * **************************************************************** VSE/POWER execution reader task analyses * $$ PUN MEM=... statement with phase IPW$$XJ and the extracted parameters are passed in a work area to the new execution writer task designated for punching the data into the AF sublibrary. If the next card read by execution reader task is also a JECL statement, e.g. * $$ SLI..., it will be processed by IPW$$XJ and IPW$$XJ may refer to the parameter work area accessing it via the new task. On fast processors ( D/T3906 , D/T3907, D/T8561 , D/T8562 ) the transfer of the work area may not be completed. Then VSE/POWER uses an empty work area pointer to address storage outside of the partition, which abends VSE/POWER. PSW in message 1Q2CI will point to IPW$$XJ at offset x255E.
Problem conclusion
Code in IPW$$XJ will now assure that work area is chained immediately to new execution writer task so that it can be addressed directly after attaching the task.
Temporary fix
Comments
APAR Information
APAR number
DY47843
Reported component name
VSE/POWER
Reported component ID
5686VS603
Reported release
62C
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-11-04
Closed date
2020-11-26
Last modified date
2020-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UD54389
Modules/Macros
IPW$$XJ IPW$$XWE
Fix information
Fixed component name
VSE/POWER
Fixed component ID
5686VS603
Applicable component levels
R62C PSY UD54389
UP20/12/02 I 1000 ¢
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG32M","label":"APARs - VSE\/ESA environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"62C"}]
Document Information
Modified date:
03 December 2020