Troubleshooting
Problem
Data inconsistencies may be detected on a MegaRAID logical volume if the logical volume has an on-going background operation in progress and a system reset occurs.
Resolving The Problem
Source
RETAIN tip: H19554
Symptom
Data inconsistencies may be detected on a MegaRAID logical volume if the logical volume has an on-going background operation in progress and a system reset occurs.
Affected configurations
This tip is not machine specific.
The following firmware level(s) are affected:
1.02.02-0167 and belowThe system is configured with one or more of the following IBM Options:
The MegaRAID firmware for the version 1.02.02-0167 is affected.
The system is configured with at least one of the following:
Note: This does not imply that the network operating system will work under all combinations of hardware and software.
Please see the compatibility page for more information:
http://www.ibm.com/servers/eserver/serverproven/compat/us/ |
Solution
IBM strongly recommends applying MegaRAID Firmware image version 1.03.20-0400 or higher.
The file is available from the IBM System x Support web site at the following URL:
http://www.IBM.com/systems/support/ |
Additional information
When a logical volume is running a background I/O operation such as an "initialization" or a "consistency check", and the system is rebooted, there is a very low probability for the controller to acknowledge a complete I/O to the host operating system prior to the I/O being completed.
This is a rare issue can result in data corruption on the logical volume, and as a result, the user would see errors reported by the operating system or an application.
Document Location
Worldwide