Adjust Time (QWCADJTM) API
Required Parameter Group:
1 | Adjustment variable | Input | Char(*) |
2 | Length of adjustment variable | Input | Binary(4) |
3 | Adjustment format name | Input | Char(8) |
4 | Error Code | I/O | Char(*) |
Default Public Authority: *USE
Threadsafe: YES
The Adjust Time (QWCADJTM) API will adjust the time by increasing or decreasing the time-of-day clock to a maximum change of plus or minus two hours.
Note: A time-of-day adjustment will remain active until completed unless one of the following occurs:
- A new time-of-day clock adjustment is started for the system.
- The time-of-day clock for the system is changed.
- The system is powered off.
The Retrieve System Time Information(QWCRTVTM) API can be used to determine if an adjustment to the time-of-day clock is allowed and can be used to retrieve information on any time adjustment that may be currently active.
Authorities and Locks
- User Special Authority
- *ALLOBJ
Required Parameter Group
- Adjustment variable
- INPUT; CHAR(*)
The variable that is used to specify the time adjustment details.
- Length of adjustment variable
- INPUT; BINARY(4)
The length of the adjustment variable. Minimum length is 9 bytes.
- Adjustment format name
- INPUT; CHAR(8)
The format name of the adjustment variable. The possible format name is:
- ADJT0100
- Basic time adjustment details.
See Format of Adjustment Variable for more information.
- Error code
- I/O; CHAR(*)
The structure in which to return error information. For the format of the structure, see Error code parameter.
Format of Adjustment Variable
The following table describes the order and format of the data that is specified in the adjustment variable. For detailed descriptions of the fields in this table, see Field Descriptions.
ADJT0100
Offset | Type | Field | |
---|---|---|---|
Dec | Hex | ||
0 | 0 | BINARY(8), UNSIGNED | Time adjustment amount |
8 | 8 | CHAR(1) | Time adjustment direction |
Field Descriptions
Time adjustment amount. The time value which specifies the amount of time in microseconds by which the time-of-day clock will be increased or decreased.
Note: The maximum value for the time adjustment interval is two hours.
Time adjustment direction. The direction of the time-of-day clock adjustment for the system.
0 | Increase time of day. |
1 | Decrease time of day. |
Error Messages
The following messages may be sent from this function:
Message ID | Error Message Text |
---|---|
CPF1890 E | *ALLOBJ authority required for requested operation. |
CPF18C5 E | Time adjustment not valid. |
CPF24B4 E | Severe error while addressing parameter list. |
CPF3C12 E | Length of data is not valid. |
CPF3C21 E | Format name &1 is not valid. |
CPF3C36 E | Number of parameters, &1, entered for this API was not valid. |
CPF3C3C E | Value for parameter &1 not valid. |
CPF3CF1 E | Error code parameter not valid. |
CPF3CF2 E | Error(s) occurred during running of &1 API. |
CPF9821 E | Not authorized to program &1 in library &2. |
CPF9872 E | Program or service program &1 in library &2 ended. Reason code &3. |