After you install
the ProtecTIER® servers,
you must install the TSSC, KVM components,
and TSSC Ethernet
switch.
Attention: If the customer
does not have a preexisting TSSC, but purchased a TSSC with the gateway,
you are required to install it and its related components, along with
the other gateway hardware. Not installing, connecting, and configuring
the TSSC (either purchased or preexisting) in accordance with this
installation roadmap causes the ProtecTIER server
configuration procedure later in this document to fail.
Before you begin
Step
2 in
the following procedure directs you to use the Gateway Installation
Instructions for
IBM Rackmount TSSC/USB Modem/Ethernet Switch/KVM,
PN 35P1220, installation instruction to install the TSSC, TSSC Ethernet
switch, TSSC USB modem, and KVM assembly. Consider installing the
KVM assembly and TSSC Ethernet switch below the TSSC in the rack,
as documented in the following procedure.
Procedure
- Install the 8-port KVM switch. See Figure 1.
- Install the L-brackets 1 onto
the KVM switch 2 , using the four slotted
pan head screws 3 provided. Mount the brackets as far forward on the switch as
possible.
- Remove the three screws 4 that
are in the lower position on the rails at EIA Unit 19, holes 2 and
3.
- Slide the switch onto the rails.
- Secure the KVM switch to the rack with the three screws
that you removed in step 1.b.
Figure 1. Installing
the KVM switch
- See the IBM Rackmount TSSC/USB
Modem/Ethernet Switch/KVM, PN 35P1220, provided with the TSSC server, for
the most current installation instructions for the TSSC server and
server rails, TSSC USB modem, TSSC Ethernet switch, and the KVM assembly. The optimal location for installing the TSSC is in EIA
Unit 18. Use EIA holes 52, 53, and 54 for the installation of the
rail assembly for the TSSC. Make sure
that the rail pins extend through holes 52 and 53 at the front and
rear of the frame.
- Mount the KVM assembly and TSSC Ethernet switch
directly under the TSSC in
EIA Unit 17. Use EIA holes 49, 50, and 51 for the installation of
the KVM rail assembly. Place the mounting clips in holes 49 and 51
(EIA Unit 17) in the front and rear of the frame. Use the rail assembly
mount position at the rear of the frame to secure the TSSC Ethernet switch
when added after the KVM assembly is installed.