No macro - is type 3, gets no lock.
Calls module IFBSVC76, entry point IGC0007F.
APF protected. GTF data is:
- R15
- Contains a return code, as follows:
- Return Code (hex)
- Explanation
- 00
- Recording to logrec recording medium complete
- 08
- Storage not available (no recording attempted)
- 0C
- One of the following:
- Space not available (no recording attempted). Record override
switch set.
- Buffer overflow condition reached for log stream blocks.
- 10
- One of the following:
- Permanent I/O error.
- Format error in the header record.
- 14
- Record length error; the record would not fit in a logrec log
stream block.
- R0
- If positive, contains the function indicator in byte 3:
- 00
- Indicates that the EOD recording is requested.
- 04
- Indicates that the EREP entry to record statistical information
in the logrec data set is requested.
- 08
- Indicates that an IPL recording is requested.
- 0C
- Indicates entry to update date and time values in the logrec
data set time-stamp record.
If negative (complemented), contains the length in bytes of
a record to be placed in the logrec set.
- R1
- If R0 is positive, R1 contains no applicable data. If R0 is
negative, R1 contains the address of the record to be written.