A protection exception (abend 0C4) or privileged operation (abend
0C2) occurred while:
- IEAVTRER (RECORD macro processing) was in control and the RCB
buffer was not being manipulated by the requesting routine,
- The recording task (IEAVTRET) was in control and the error was
not an operation exception (abend 0C1).
This abend is not a permanent error type.
The areas dumped are LPA, NUC, PSA, SQA, and SUM.