Information is provided to identify the coupling facility to which the structure is connected. For each type of structure, specific information, such as group name and exit address, is provided. This report will also display information when XES recovery is being performed. For lock and serialized list structures, the signal activity on the system is formatted to give you the status of signals for a structure to and from other connections. For cache structures, the NAMECLASSMASK in use for a structure is reported if applicable.
COMMAND===> XESDATA CONNECTION DETAIL CONNAME(HNGTME3#SYS2)
***** XESDATA (CROSS-SYSTEM EXTENDED SERVICES) REPORT *****
Options list:
Report(s).............. CONNECTION
Level(s) of detail..... DETAIL
Filter(s) in use....... NONE
Sysplex name.............. PLEX1
System name............... B7VB0032
Facility name............. LF01
Structure name......... CACHE01
ASID................ X'002A'
Connection name.. HNGTME3#SYS2
Structure name......... IXCTL_SIGNAL03
ASID................ X'0006'
Connection name.. SIGPATH_02000003
***** CONNECTION DETAIL REPORT *****
CONNECTIONS DEFINED IN THE SYSTEM
---------------------------------
Connect Name................... HNGTME3#SYS2
Connection Function......... NOT SPECIFIED
ConToken.................... IXCLO002 7F509A00 00030001
Connection Identifier....... 03
Connection Version.......... 00030001
Connection Disposition...... Delete
Connection Status........... Active
ASID........................ X'002A'
Job name.................... MAINASID
TCB address................. 004E17E0
Address Space STOKEN........ 000000A8 00000003
Connect Data................ 00000000 0AF84BB0
Connect Level............... 00000000 00000000
Operational CF Level........ 00000008
Structure rebuild allowed... Yes
Duplexing rebuild allowed... No
System-managed support...... No
Termination level........... Task
Critical Connector.......... No
Connection is failure isolated
Outstanding Responses:
Have not received a response to the disconnected/failed connection event
Started monitoring...... 09/15/2009 12:36:42.743800
Subject Connection Name. HNGTME3#SYS3
MON address............. 7FFD1468
Response is overdue
Maximum hang interval (CFSTRHANGTIME).. 45 seconds
Next hang relief action time........... 09/15/2009 12:39:37.086051
Component Trace Information:
Current Trace Buffer................. Connector
Current Options...................... Lockmgr
Connect
Signal
Request
Recovery
Hwlayer
Config
Global Trace Buffer Address.......... 00001000
Global Trace Buffer Size ............ 16383 K
Global Trace Buffer Data Space Name.. IXLCTCAD
Connect Trace Buffer Address......... 01841000
Connect Trace Buffer Size ........... 4095 K
Connect Trace Buffer Data Space Name. IXLCTCAD
Structure and Facility Information:
Structure Name....................... CACHE01
Structure Type....................... Cache
Structure Logical Version............ C4CB0ABC C97FA120
Structure Disposition................ Delete
Structure ID......................... 0003
Structure Physical Version........... C4CB0ABC C97FA120
Facility Name........................ LF01
Facility ID.......................... 00000001
Facility CFLevel..................... 16
Structure Specific Information:
Event Exit Address.................. 0AE61F90
Complete Exit Address............... 00FDBD42
Number of Directory Entries......... 15933
Structure has data elements......... Yes
Total Data Elements Defined...... 15933
Data Element Size in Bytes....... 256
Maximum data elements per entry.. 1
Structure has adjunct data.......... No
Number of Storage Classes........... 1
Number of Castout Classes........... 1
UDF Order Queue maintained.......... No
Name class mask..................... 0000
Vector Token........................ 02134840 62973198 00000728
Diag128: 00000001 Diag129: 0049C0E8 00000003
Diag001: 02357B90 Diag002: 7F509A00 Diag003: 02134718
Diag586: 00000000
Connect Name................... SIGPATH_02000003
Connection Function......... NOT SPECIFIED
ConToken.................... IXCLO014 7EEB1900 00020001
Connection Identifier....... 02
Connection Version.......... 00020001
Connection Disposition...... Delete
Connection Status........... Active
ASID........................ X'0006'
Job name.................... XCFAS
TCB address................. 004F9238
Address Space STOKEN........ 00000018 00000001
Connect Data................ 7EE47768 00000000
Connect Level............... 00000000 00000000
Operational CF Level........ 00000010
Structure rebuild allowed... Yes
Duplexing rebuild allowed... No
System-managed support...... No
Termination level........... XCF signaling
Critical Connector.......... No
Connection is not failure isolated
Outstanding Responses:
No Outstanding Responses
Component Trace Information:
Current Trace Buffer................. Connector
Current Options...................... Lockmgr
Connect
Signal
Request
Recovery
Hwlayer
Config
Global Trace Buffer Address.......... 00001000
Global Trace Buffer Size ............ 16383 K
Global Trace Buffer Data Space Name.. IXLCTCAD
Connect Trace Buffer Address......... 01041000
Connect Trace Buffer Size ........... 4095 K
Connect Trace Buffer Data Space Name. IXLCTCAD
Structure and Facility Information:
Structure Name....................... IXCTL_SIGNAL03
Structure Type....................... List
Structure Logical Version............ 00000000 00000000
Structure Disposition................ Delete
Structure ID......................... 0001
Structure Physical Version........... C4CB08D4 8B5E884C
Facility Name........................ LF01
Facility ID.......................... 00000001
Facility CFLevel..................... 16
Structure Specific Information:
Event Exit Address.................. FF5E71A8
Complete Exit Address............... FF506100
List Transition Exit Address........ FF50D938
Number of List Headers.............. 64
Number of List Entries.............. 1580
Number of Event Monitor Controls.... 0
Structure has data elements......... Yes
Total Data Elements Defined...... 1562
Data Element Size in Bytes....... 4096
Maximum data elements per entry.. 16
Structure has adjunct data.......... Yes
Key Support......................... No
Secondary Key Support............... No
Name Support........................ No
Entry ID assigned by................ CF
Vector Token........................ 027F6420 49682968 02000721
Diag128: 00000002 Diag129: 0049C028 00000001
Diag001: 027AD960 Diag002: 7EEB1900 Diag003: 027F62F8
Diag586: 00000000
SIGNAL ACTIVITY ON THE SYSTEM
-----------------------------
IXL0017I No information to display in report.
IXL0015I No exceptional conditions were found by the CONNECTION DETAIL report.