IXG275I
SYSTEM LOGGER EVENT MONITORING STOPPED FOR SERVICE TASKS ON SYSTEM sysname

Explanation

The system requested system logger service task monitoring to be stopped because of operator response of "EXIT" for message IXG272E. No more system logger service task event monitoring will be performed on this system, unless system logger or the system is restarted.

In the message text:
sysname
is the name of the system where the service task monitor has been stopped.

System action

System logger will no longer monitor service task events, including allocation and recall requests. This response will not affect offload monitoring.

Operator response

Contact the system programmer.

System programmer response

Make sure that system logger is still functioning normally. If monitoring is essential to installation operations, consider taking down the IXGLOGR address space (this will not impact any executing system logger applications) and then restarting system logger (through START IXGLOGRS).

User response

None.

Programmer response

Correct the error and retry the operation.

Source

System logger (SCLOG)

Routing code

10

Descriptor code

4