IXL041E
CONNECTOR NAME: connector-name, JOBNAME: jobname, ASID: asid HAS NOT RESPONDED TO THE event FOR SUBJECT CONNECTION: subject-connector-name. process FOR STRUCTURE structure-name CANNOT CONTINUE. MONITORING FOR RESPONSE STARTED: mondate montime. DIAG: x

Explanation

An XES process is in a possible hang condition because the indicated connector did not provide a required response to an event. In the message text:
connector-name
Connection name of the connector failing to provide the required response.
jobname
Jobname of the connector failing to provide the required response.
asid
ASID of the connector failing to provide the required response.
event
The event to which the connector has not responded.
  • DISCONNECTED/FAILED CONNECTION EVENT
  • REBUILD CONNECT FAILURE EVENT
subject-connector-name
Connection name of the connector that disconnected from the structure or suffered a rebuild connect failure.
process
XES process that cannot continue until the specified connector provides the required response.
  • REBUILD PROCESSING
  • DUPLEXING REBUILD PROCESSING
  • DISCONNECT/FAILURE PROCESSING
structure-name
The name of the structure.
mondate
The date when the system started waiting for a response (mm/dd/yyyy). The date is in months (01–12), days (01–31), and year.
montime
The time when the system started waiting for a response (hh:mm:ss). The time is in hours (00–23), minutes (00–59), and seconds (00–59).
x
Diagnostic data

System action

The XES process cannot continue until all the necessary responses are received from all active connectors. The system issues message IXL049E stating whether it will initiate automatic hang relief action and if so, at what time. The system may also issue ABEND X'026' reason X'08118001' and initiate a dump.

If the hung connector provides the overdue response or the system terminates the hung process or connector, the system issues message IXL048I.

Operator response

Notify the system programmer.

System programmer response

Check on the status of the indicated connector and the system on which the connector is running. Take appropriate action to correct the situation or cancel/terminate the connector if necessary. If it is necessary to terminate the connector, first collect diagnostic information for the application causing the hang condition. The following information should be collected: system log, application log, and an appropriate dump (the dump generated by the ABEND X'026' reason X'08118001', if applicable). Then, using the application's instructions, end the connection not providing the desired response.

Source

Cross System Extended Services (XES)

Module

IXLM1TMR

Routing code

2,10

Descriptor code

7,11