XES HARDWARE SUPPORT IS NOT INSTALLED. REASON: hdwreas
Explanation
XES was unable to initialize coupling facility
related functions because the required hardware support is not installed
on this system. In the message text:
- hdwreas
- Reason code describing which particular component of coupling
facility hardware support was not present.
- 1
- Neither XES (Message Facility)-support instructions nor channel
subsystem call support are installed.
- 2
- XES (Message Facility)-support instructions are not installed.
- 3
- Channel subsystem call support is not installed.
- 4
- Channel subsystem call has failed.
System action
The system continues without the ability to use
XES services.
Operator response
System programmer response
If you are trying to use a coupling
facility, record the reason code (hdwreas) and
contact hardware support. If you are not trying to use a coupling
facility, you can ignore this message. (The system checks to see if
coupling facility hardware is present and issues this message whenever
the hardware support is not installed.)
Source
Cross System Extended Services (XES)
Module
Routing code
Descriptor code