IXL011I
XES HARDWARE SUPPORT IS NOT INSTALLED. REASON: hdwreas

Explanation

XES was unable to initialize coupling facility related functions because the required hardware support is not installed on this system. In the message text:
hdwreas
Reason code describing which particular component of coupling facility hardware support was not present.
1
Neither XES (Message Facility)-support instructions nor channel subsystem call support are installed.
2
XES (Message Facility)-support instructions are not installed.
3
Channel subsystem call support is not installed.
4
Channel subsystem call has failed.

System action

The system continues without the ability to use XES services.

Operator response

Not applicable.

System programmer response

If you are trying to use a coupling facility, record the reason code (hdwreas) and contact hardware support. If you are not trying to use a coupling facility, you can ignore this message. (The system checks to see if coupling facility hardware is present and issues this message whenever the hardware support is not installed.)

Source

Cross System Extended Services (XES)

Module

IXLI1SIN

Routing code

1,2,10

Descriptor code

12