IXC232I
typename FUNCTION NOT ACTIVATED: process IN PROGRESS

Explanation

This system was unable to initiate use of the named function because the couple data set configuration was changing. Either permanent error (couple data set removal) or ACOUPLE was in progress.

In the message text:
typename
The couple data set function type that could not be activated.
process
One of the following:
PERMANENT ERROR
Permanent error is in progress for the named function.
ACOUPLE
ACOUPLE is in progress for the named function.

System action

If this message is issued during XCF initialization, the system prompts with messages IXC239A and IXC252D. If it is issued after XCF initialization is complete, the system continues running without access to the named function.

Operator response

Wait until the permanent error or ACOUPLE process has completed on the systems that are using the named function. If prompted with IXC239A / IXC252D, reply 'R' to IXC252D to retry couple data set allocation. If not prompted, issue the SETXCF COUPLE,PCOUPLE command to bring the named function into use.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCL1AFN

Routing code

1,2

Descriptor code

12