IXG302E
DATA MAY BE LOST FOR LOG STREAM logstream IN STRUCTURE strname DUE TO I/O ERROR.

Explanation

System logger encountered an I/O error while offloading the log stream data for log stream logstream.

The I/O error was encountered while writing the control interval which was not completely written during prior writer offload. The log blocks which were part of the control interval and offloaded previously may be lost.

In the message text:
logstream
is the name of the log stream for which data was being offloaded.
strname
is the name of the structure associated with the log stream.

System action

System logger marks that the log stream has a loss of data condition. This condition is communicated to applications when the application attempts to Browse the log stream and gap condition is detected or when the application attempts to write more blocks to the log stream.

Operator response

None.

System programmer response

None.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)

Module

IXGA1WRT

Routing code

10

Descriptor code

4