IXG223I
ENTRY TO ELEMENT RATIO CHANGE INITIATED FOR STRUCTURE strname SUBSEQUENT REBUILDS MAY FAIL

Explanation

A request has started to alter the entry to element ratio for a system logger structure strname by an agent other than system logger. The system logger is unable to track the target entry to element ratio in the TYPE=LOGR couple data set because it is not formatted at the correct level. A subsequent rebuild for this structure may fail as a result of this change because system logger will connect to the new instance of the structure with the entry to element ratio as defined through the AVGBUFSIZE keyword on the structure definition in the TYPE=LOGR policy.

In the message text:
strname
is the name of the structure.

System action

System logger continues processing.

Operator response

Notify the system programmer.

System programmer response

Determine whether it is acceptable for an application to initiate an alter of a system logger structure and change the structures entry to element ratio. If so, you should format a new couple data set with TYPE=LOGR and bring it into the sysplex as the active primary TYPE=LOGR couple data set. This allows system logger to track the entry to element changes so that it can use them on subsequent structure allocations. If it is not acceptable for an application to change the entry to element ratio for a system logger structure, then determine which application initiated the alter and either change the application or remove the applications authority to alter the structure.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)

Module

IXGC3SEX

Routing code

-

Descriptor code

-