IXG222I
SEVERE STRUCTURE STORAGE SHORTAGE DETECTED IN STRUCTURE strname AFTER ALTER PROCESSING.

Explanation

As a result of a structure alter operation (from a SETXCF START,ALTER command or an IXLALTER request for example), system logger determined that the structure allocated for this log stream is not large enough to support the current number of log streams connected to the structure.

In the message text:
strname
is the name of the structure associated with the SCF ALTER request.

System action

IXGWRITE requests issued by current connectors may fail unless the structure size is increased.

Operator response

Use the SETXCF ALTER command support to increase the structure size.

System programmer response

Changes may need to be made to the XCF Policy in insure the minimum structure size is adequate.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)

Module

IXGF1DSR

Routing code

1

Descriptor code

11