IXG105I
UNABLE TO START STRUCTURE REBUILD INTO STRUCTURE strname FOR REASON: text DIAG1: diag1 DIAG2: diag2

Explanation

The initiation of the structure rebuild process for the specific reason has failed.

In the message text:

strname
is the new structure in the rebuild operation.
text
is one of the following:
STRUCTURE FAILURE
A structure failure condition was detected.
LOSS OF CONNECTIVITY TO THE STRUCTURE
Connectivity to the structure does not exist.
COUPLING FACILITY VOLATILITY STATE CHANGE
A structure has changed from non-volatile to volatile state.
diag1
Is the return code from the IXLREBLD macro.
diag2
Is the reason code from the IXLREBLD macro.

System action

The request to initiate a structure rebuild was not successful.

Operator response

If another system within the sysplex connected to structure name could not initiate a structure rebuild, a SETXCF START,REBUILD,STRNAME=name console command can be issued to to initiate a structure rebuild.

System programmer response

Consult z/OS MVS Programming: Sysplex Services Reference to understand the meaning of the return code and reason code received from IXLREBLD, as this may help you solve the problem. If a structure rebuild can not be initiated automatically by system logger or initiated manually by the SETXCF console command issued by the operator, search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM® Support Center.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)

Module

MANY

Routing code

1

Descriptor code

11