No Couple Data Set of type LOGR is available. Either make a Couple Data Set of type LOGR available so that IXGLOGR address space initialization can continue or reply C to cancel the IXGLOGR address space.
Processing for the requested system logger service stops. The system issues message IXG054 to prompt the operator to make a LOGR couple data set available or to reply C to cancel the request from the named job. If a LOGR couple data set becomes available, then IXGLOGR address space continues processing the request. If the operator replies C then the IXGLOGR address space rejects the request.
Make a valid LOGR couple data set available if system logger services are intended to be available for operation at the installation. Otherwise, reply C.
None.
None.
None.
System logger (SCLOG)
IXGBLF01
1,2
2