IXC538I
DUPLEXING REBUILD OF STRUCTURE strname WAS NOT Start of change{INITIATED|STOPPED}End of change BY MVS. REASON: reason

Explanation

Start of changeAn event occurred that triggers the system to take action to start or stop a duplexing rebuild for the structure. Action was not taken due to the provided reason. This may mean that the environmental conditions required for a duplexing rebuild have not all been met, and may not necessarily require urgent action.End of change

In the message text:
strname
The name of the structure
action
The word INITIATED or STOPPED
reason
One of the following:
STRUCTURE NOT DEFINED IN THE CFRM ACTIVE POLICY
The structure is not defined in the CFRM active policy and therefore is not allocated in any coupling facility.
STRUCTURE NOT ALLOCATED
The structure is not allocated in any coupling facility.
AT LEAST ONE ACTIVE CONNECTION INDICATED THAT REBUILD IS NOT ALLOWED
Rebuild not permitted because IXLCONN with ALLOWREBLD=NO was specified by at least one active connection.
Start of changeDEFERRED UNTIL PROCESS COMPLETIONEnd of change
Start of changeA duplexing rebuild could have been initiated or stopped, but the action is instead deferred. The action is deferred to prevent duplexing rebuild processing from interfering with other potentially more important processing. If necessary, the system will attempt to take action once none of the following processing is in progress: REBUILD (other than the duplex established), REALLOCATE, POPULATECF, and LOSSCONN RECOVERY. The DISPLAY,SCF,STRUCTURE,STATUS=(RBPROC,RPEND,LOSSCONN) can be used to display structures associated with processing that is causing the deferral.End of change
COUPLE DATA SET FOR CFRM NOT AVAILABLE
The couple data set for CFRM is not available to this system.
NO ACTIVE CONNECTIONS TO THE STRUCTURE
The structure has no connectors to participate in rebuild.
REBUILD STOP IS IN PROGRESS FOR THE STRUCTURE
Rebuild stop is in progress for the structure.
XES FUNCTION NOT AVAILABLE
XES functions are not available. This can be because the hardware necessary to provide XES functions is not present.
AN UNEXPECTED ERROR OCCURRED
An unexpected error occurred during rebuild processing.
NO ELIGIBLE STRUCTURES FOUND IN COUPLING FACILITY
On a rebuild start request, no structures eligible for rebuild were found in the coupling facility specified. On a rebuild stop request, no structures eligible for rebuild stop were found in the coupling facility specified.
COUPLING FACILITY NOT DEFINED IN THE CFRM ACTIVE POLICY
The coupling facility is not defined in the CFRM active policy.
NO COUPLING FACILITY PROVIDED BETTER CONNECTIVITY
No other coupling facility has better connectivity than the current one. The rebuild, which was initiated due to a loss of connectivity, would cause a further degradation in connectivity if accepted. The system evaluated the set of active connections that lost connectivity to the current structure as compared with the set of active connections that would not be able to connect to the rebuild new structure. The system terminates structure rebuild processing because the result of the rebuild would cause additional active connections to lose connectivity.
NO COUPLING FACILITY PROVIDED BETTER OR EQUIVALENT CONNECTIVITY
No other coupling facility has better connectivity than the current one. The rebuild would cause a degradation in connectivity as determined by SFM system weights, if accepted.
DUPLEXING REBUILD NOT ALLOWED FOR THE STRUCTURE
The structure does not support duplexing rebuild for one of the following reasons:
  • DUPLEX(DISABLED) was specified or defaulted to in the CFRM active policy for the structure.
  • There are failed persistent connections that are unavailable until a larger CFRM couple data set is made available.
  • A user-managed duplexing rebuild could not be started because:
    • User-managed duplexing rebuilds are not supported for the structure type.
    • At least one active or failed-persistent connection specified or defaulted to IXLCONN ALLOWDUPREBLD=NO.
  • A system-managed duplexing rebuild could not be started because:
    • The structure has at least one active connector, and none of the connectors (active or failed-persistent) specified IXLCONN ALLOWAUTO=YES when connecting.
    • A system-managed duplexing rebuild is not supported when a CFRM policy change is pending for the structure.
STRUCTURE HAS FAILED
The request was to start a duplexing rebuild and the structure has failed. Duplexing rebuild is not allowed when the structure is in the failed state.
NO OTHER COUPLING FACILITY FOUND IN PREFERENCE LIST
SETXCF START,REBUILD was requested and LOCATION=OTHER was either specified on the rebuild request or defaulted to for STARTREASON=LOSSCONN or for a request to start a duplexing rebuild. In addition to avoiding the coupling facility in which the structure is currently allocated, when a duplexing rebuild is stopped by the operator and DUPLEX(ENABLED) is specified in the active policy, the subsequent duplexing request initiated due to DUPLEX(ENABLED) will avoid the coupling facility in which the previous instance of the structure was allocated when the duplexing rebuild was stopped.
STRUCTURE DOES NOT SUPPORT SYSTEM-MANAGED PROCESSES
The structure does not support system-managed processes (for example, rebuild) for one of the following reasons:
  • The structure was not allocated in a coupling facility at or above the minimum CFLEVEL required for the current process by a system supporting system-managed processing.
  • The structure has connections that have not been reconciled into the CFRM active policy.
  • Structure cleanup is in progress for the structure.
CONNECTORS DO NOT SUPPORT SYSTEM-MANAGED PROCESSES
The requested system-managed process cannot be initiated for one of the following reasons:
  • The structure has at least one active connector and at least one of the connectors (active or failed-persistent) did not specify IXLCONN ALLOWAUTO=YES when connecting.
  • A duplexing rebuild cannot be initiated for a structure that has only failed-persistent connectors, and at least one of the failed-persistent connectors did not specify IXLCONN ALLOWAUTO=YES when connecting.
NO SUITABLE COUPLING FACILITY IN PREFERENCE LIST
The requested system-managed process cannot be initiated for one or more of the following reasons:
  • The preference list is empty.
  • The preference list contains no other coupling facility at or above the minimum CFLEVEL required for the current process.
  • A potentially suitable coupling facility does not permit structure allocation.
AT LEAST ONE CONNECTOR HAS LOST CONNECTIVITY TO THE STRUCTURE
The requested system-managed process (for example, rebuild) cannot be initiated because one or more of the connectors to the target structure has lost connectivity.
CFRM COUPLE DATA SET DOES NOT SUPPORT SYSTEM-MANAGED PROCESS
The CFRM couple data set does not support the requested system-managed process (for example, rebuild), because the CFRM couple data set was not formatted at or above the minimum version for the system-managed process requested. Use the DISPLAY XCF,COUPLE,TYPE=CFRM command to determine the format of the CFRM couple data set. To support system-managed rebuild the CFRM couple data set should be formatted specifying “ITEM NAME(SMREBLD) NUMBER(1)”. For system-managed duplexing rebuild, “ITEM NAME(SMDUPLEX) NUMBER(1)” should also be specified when formatting a CFRM couple data set. Specifying “ITEM NAME(SMDUPLEX) NUMBER(1)” implicitly formats a CFRM couple data set that supports both system-managed rebuild and system-managed duplexing rebuild.
STRUCTURE WITH NO CONNECTORS HAS NEVER BEEN SYSTEM-MANAGED DUPLEXED
A system-managed duplexing rebuild cannot be initiated because there are no connections to the structure and the structure has not previously been duplexed using system-managed processing.
ALLOCATION OF REBUILD NEW STRUCTURE FOR DUPLEXING REBUILD NOT FEASIBLE
Allocation of the rebuild new structure instance in support of a duplexing rebuild is not feasible. Message IXC574I will contain additional diagnostic information.
Start of changeSTRUCTURE OBJECTS IN STORAGE-CLASS MEMORYEnd of change
Start of changeThe duplexing rebuild could not be started because storage-class memory is in use.End of change

System action

Not applicable.

Operator response

Not applicable.

System programmer response

Not applicable.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCL2BLD

Routing code

10

Descriptor code

-