IXC505I
STRUCTURE strname IN COUPLING FACILITY type.mfg.plant.sequence PARTITION: partition side CPCID: cpcid status TRACE THREAD: thread.

Explanation

Action was taken against the coupling facility or the CFRM active policy for a given structure. The coupling facility containing named structure is identified by the node descriptor. See mapping IXLYNDE.

In the message text:

strname
Name of the structure for which information is recorded.
type
Node type (see ndetype in IXLYNDE).
mfg
Node manufacturer ID (see ndemfg in IXLYNDE).
plant
Node manufacturer plant ID (see ndeplant in IXLYNDE).
sequence
Node sequence number (see ndesequence in IXLYNDE).
partition
Node LPAR partition number (see ndepartition in IXLYNDE).
side
The node PP/SI mode indicator and configuration code from the IXLYNDE are used to determine the value for side. side is one of the following:
SIDE: 0
The coupling facility is on SIDE 0 of a partitionable CPC.
SIDE: 1
The coupling facility is on SIDE 1 of a partitionable CPC.
blank
The coupling facility is in a non-partitionable CPC.
cpcid
Node Central Processor Complex (CPC) ID (see ndecpcid in IXLYNDE).
status
One of the following:
DEALLOCATED.
The non-persistent structure was found in both the CFRM active policy and the coupling facility. All non-persistent structures are deallocated and cleared from the CFRM active policy during coupling facility cleanup.
NOT FOUND IN COUPLING FACILITY. CFRM ACTIVE POLICY CLEARED.
The structure described in the CFRM active policy is not allocated in the coupling facility. The CFRM active policy structure information has been updated to indicate that the structure is not allocated.
NOT FOUND IN THE CFRM ACTIVE POLICY. DEALLOCATED FROM COUPLING FACILITY.
The structure found in the coupling facility is not described in the CFRM active policy. It is a non-persistent structure and therefore was deallocated.
NOT FOUND IN THE CFRM ACTIVE POLICY. STRUCTURE ADDED TO THE CFRM ACTIVE POLICY.
The structure was found in the coupling facility and was added to the CFRM active policy.
NOT FOUND IN THE CFRM ACTIVE POLICY. COULD NOT BE ADDED TO THE CFRM ACTIVE POLICY.
The structure was found in the coupling facility and an attempt was made to add it to the CFRM active policy. The structure was not added to the CFRM active policy due to size constraints. Message IXC503I will be issued to indicate the changes required to add the structure to the CFRM active policy.
HAS CONNECTIONS PENDING RECONSTRUCTION INTO THE CFRM ACTIVE POLICY.
The structure in the coupling facility has connections that could not be added into the CFRM active policy. The CFRM active policy does not have enough CONNECT records to support the connections found in the coupling facility. Message IXC502I will be issued to indicate the changes required to add the connections to the CFRM active policy.
DEALLOCATED. MORE CURRENT VERSION IN THE CFRM ACTIVE POLICY.
The structure in the coupling facility is different than the structure described by the CFRM active policy. The structure in the coupling facility was deallocated. The structure in the CFRM active policy has either been allocated after the one in the coupling facility and/or is already in use by active connections in the sysplex. This can happen if the coupling facility containing the structure is brought on line after a connector has already connected to and allocated the structure in a different coupling facility.
DEALLOCATED. NEW STRUCTURE ALLOCATED FOR REBUILD WHICH HAS BEEN STOPPED.
The structure in the coupling facility is the new structure for which rebuild processing was underway before cleanup processing began. Rebuild is automatically stopped when the first system in the sysplex gains ownership of the coupling facility.
FAILED.
The structure was found in the coupling facility and experienced a failure. The CFRM active policy structure information has been updated to indicate the structure is not allocated and the structure has been deallocated.
ALLOCATED BY A DIFFERENT SYSPLEX HAS BEEN DEALLOCATED AS REQUESTED.
The structure that was found was allocated by another sysplex. The operator was prompted with messages (IXC523I and IXC508A) to determine the action.
NOT FOUND IN COUPLING FACILITY. STRUCTURE FAILURE INITIATED.
The structure described in the CFRM active policy is not allocated in the coupling facility and there are active connections to the structure. Structure failure processing has been initiated in order to notify the connections. that the structure no longer exists.
thread
Used to tie together messages and XCF component trace records for a particular coupling facility cleanup process.

System action

The CFRM active policy is updated to reflect the current state of the coupling facility.

Operator response

Not applicable.

System programmer response

Not applicable.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCL2RC

Routing code

10

Descriptor code

-