Connections to the structure reside in the coupling facility that were not able to be added into the CFRM active policy during coupling facility cleanup processing.
The connections will remain in the coupling facility until a couple data set for CFRM is obtained which is large enough to support all connections.
Notify the system programmer.
Run the XCF couple data set format utility for TYPE(CFRM) to increase the number of CONNECT records supported. Issue the SETXCF COUPLE operator command to add the new CFRM couple data set as the alternate and then PSWITCH to make the alternate couple data set the primary couple data set for CFRM.
Cross System Coupling Facility (SCXCF)
IXCL2RC
2, 10
12