Explanation
This system tried to join a sysplex, but it's primary
and alternate couple data sets are different than the ones used by
the sysplex.
In the message text:
- reason-code
- The hexadecimal reason codes are:
- Reason Code
- Explanation
- 08
- This system specified a different primary couple data set than
the rest of the sysplex.
- 0C
- This system specified a different alternate couple data set than
the rest of the sysplex.
- 10
- This system specified different primary and/or alternate couple
data sets than the rest of the sysplex.
System action
XCF tries again to initialize this system into
the sysplex. The system issues message IXC207A to prompt for a new
COUPLExx parmlib member.
Operator response
Notify the system programmer.
System programmer response
Enter the DISPLAY XCF,COUPLE command
to display the couple data sets used by the sysplex. Do one of the
following:
- Change the couple data sets specified in the COUPLExx parmlib
member for this system to match the sysplex.
- Change the COUPLExx parmlib member to specify unique data sets
to start a new sysplex for this system.
Source
Cross System Coupling Facility (SCXCF)
Module
Routing code
Descriptor code