This system lost access to the cross-system coupling facility (XCF) external time reference (ETR) clock. Either the ETR clock failed, or this system's connection to the ETR clock failed. All systems in the sysplex must use the same ETR clock.
If this message appears on every system in the sysplex, the problem is with the ETR clock itself.
The system enters a restartable wait state X'0A2'. If this system is not removed from the sysplex, the other systems will fail. The system writes a machine check record for the ETR failure.
Contact hardware support.
If the ETR clock is not synchronized when this system is restarted, this system will remove all other systems from the sysplex. All the systems will enter a nonrestartable wait state.
If the ETR clock is synchronized, this system will rejoin the other systems in the sysplex.
If this system is not restarted, another system in the sysplex issues message IXC402D. RESET this system, and reply DOWN to message IXC402D on the other system.
After the ETR clock is fixed, reIPL this system into the sysplex.