IXC378I
A NEW SYSXCF CTRACE PARMLIB MEMBER WAS SPECIFIED - TRACE WILL BE REDEFINED WITH NEW OPTIONS AND DATA PREVIOUSLY WRITTEN TO SYSXCF'S TRACE BUFFER WILL NOT BE SAVED

Explanation

The system issues this message during initialization when the following occurs:
  1. XCF encounters an error while processing a COUPLExx member and prompts the operator for a new COUPLExx member.
  2. The operator replies with a COUPLExx member that names a different CTRACE parmlib member.

System action

The system does not save previously defined trace data in the trace buffer. XCF component trace continues tracing with the options specified in the new parmlib member.

Operator response

Verify that the options pointed to by the current COUPLExx member are the desired options. Options can be changed using the TRACE CT command. Options and buffer size can be changed by reinitializing the system.

System programmer response

Ensure that the COUPLExx member points to the correct CTIXCFxx parmlib member.

Source

Cross System Coupling Facility (SCXCF)

Routing code

1, 2

Descriptor code

12