One or more log streams defined to a structure has encountered a structure entry threshold condition. This means that the structure had 90% of the entries in use at one time. When the entries reach 100%, write operations to all of the log streams in the structure fail until the full condition is resolved. Applications using the affected log streams might experience a slow down or possibly an outage if the condition is not resolved timely.
This condition might not indicate a problem for a log stream that does not share its structure with other log streams. Also, a log stream indicated below might be the consequence of a misconfiguration of another log stream that resides in the same structure as the listed log stream.
The report keeps track of the most recent 16 entry threshold conditions that occurred. A log stream is reported only once in the list for entry threshold conditions, but might also have structure full or staging data set full conditions.
The system continues processing.
Report this problem to the system programmer.
After correcting a log stream condition, consider using the MODIFY command to update the 'TIME(mm/dd/yyyy hh:mm:ss)' parameter to a time after this condition occurred so it is no longer displayed as an exception. See the IBM Health Checker for z/OS User's Guide for instructions on updating the parameters of the check.
n/a
System logger (SCLOG)
IXGHC1CK
-
12
n/a