IXG735I
LOGGER PARAMETER PROCESSING FAILED FOR request REASON: reason

Explanation

Logger parameter processing failed.

In the message text:
request
One of the following:
  • SET IXGCNF REQUEST
  • SETLOGR REQUEST
  • STARTUP IXGCNF PROCESSING
reason
One of the following:
  • IXGCNF MEMBER ERROR
  • SETLOGR COMMAND ERROR
  • PARMLIB ALLOCATION FAILURE
  • PARMLIB SERVICE LOAD ERROR
  • ZAI SERVER CONNECTED
  • THE REQUEST FAILED FOR AN UNEXPECTED REASON

System action

No logger parameters are changed, system logger processing continues

Operator response

Notify the system programmer.

System programmer response

For IXGCNF MEMBER ERROR, correct errors noted by IXG732I messages and submit a SET IXGCNF command. For SETLOGR COMMAND ERROR, correct errors noted by IXG732I messages and re-submit the SETLOGR command. For ZAI SERVER CONNECTED, remove the SERVER or PORT options from your request or quiesce the z/OS® IBM zAware connections and re-submit the request by a SET IXGCNF or SETLOGR request. For PARMLIB ALLOCATION FAILURE, determine why SYS1.PARMLIB can not be allocated or contact IBM® Support. For other reasons, contact IBM Support.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)

Module

IXGE3CNF

Routing code

2

Descriptor code

4,5