IXG315I
SYSTEM LOGGER OFFLOAD DATA SET SWITCH OCCURRED FORREASON: reasonLOGSTREAM=logstreamDSN=datasetname

Explanation

System logger determined that a premature offload data set switch was necessary due to reason. The data set named by IXG315I is closed and a new data set is allocated. Offload processing continues.

In the message text:
reason
Is one of the following:
IO ERROR
An I/O error occurred accessing the named data set.
DATASET MIGRATED
The named data set was migrated and the log stream is defined with OFFLOADRECALL=NO.
RECALIBRATION NEEDED
The logger determined that a data set switch was needed based on internal factors.
UNABLE TO ACCESS DATASET
The logger was unable to access the data set and switched to a new one to avoid delays.
logstream
Is the name of the log stream for which the switch occurred.
datasetname
Is the data set name from which the system logger switched.

System action

System logger no longer writes to the noted offload data set. Offload processing continues on the next offload data set. See message IXG251, in the system log, for information on this data set allocation.

Operator response

None.

System programmer response

Monitor further occurrences of this message for the named log stream. If it occurs frequently for the reason of IO ERROR or RECALIBRATION NEEDED, contact IBM® support and collect documentation. Provide IBM support center with the following diagnostic information: the system logger component trace buffer dump, address space dump, structure dump (if applicable) and copies of relevant offload data sets. For more information on obtaining logger dumps, see Operator Command in an IEADMCxx Parmlib Member and Obtaining a Dump of System Logger Information in z/OS MVS Diagnosis: Tools and Service Aids.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)

Module

IXGA1SWT

Routing code

2

Descriptor code

4