IXG077I
SYSTEM LOGGER HEALTH CHECKS NOT ACTIVATED ON SYSTEM sysname REASON reason

Explanation

System logger health checks were not activated on this system. System logger encountered an error while trying to establish the system logger health checks.

In the message text:
sysname
The name of the system where health checks were not activated.
reason
Diagnostic reason code. See system programmer response for details.

System action

Logger health checks will not run on this system. No other logger processing will be adversely affected.

Operator response

Notify the system programmer.

System programmer response

Review Logrec for a system logger software record that contains PIDS/5752SCLOG RIDS/IXGBLF01, and FLDS/RETCODE VALU/H0000000C FLDS/REASON VALU/H02020007 for the service name, service type, return and reason codes.

You need to consult other publications depending on the diagnostic reason codes:
0X
There was a problem issuing a STORAGE request; consult z/OS MVS Programming: Assembler Services Reference IAR-XCT with the return code from the trace.
1X
There was a problem issuing a CSVDYNEX request; consult z/OS MVS Programming: Authorized Assembler Services Reference ALE-DYN with the return and reason codes from the trace.
2X
There was a problem issuing a HZSCHECK request; consult IBM Health Checker for z/OS User's Guide with the return and reason codes from the trace.
If the health checks are essential, you can force the IXGLOGR asid and restart system logger to retry adding the checks. If the problem cannot be determined or corrected, contact the IBM® Support Center.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)