CHECK(IBMXCF,XCF_CDS_SEPARATION) found an exception.
CDS Type Volser Data Set Name
-------- ------ --------------------------------------------
typename1 vol1 dsn1
typename2 vol2 dsn2
typename3 vol3 dsn3
Message IXCH0907I describes the complete couple data
set configuration. The system continues processing.
Report this problem to the system programmer.
For maximum performance and availability, the primary sysplex couple data set and the primary CFRM couple data set should be placed on different volumes, and the installation monitor I/O should rate to other couple data sets such as LOGR to evaluate whether they also warrant placement on separate volumes. By default, this check does not consider the LOGR couple data set in evaluating couple data set placement. If the installation requires to maintain the LOGR primary on a separate volume, update the check with the parameter 'LOGR(YES)' to require the check to consider the placement of the LOGR couple data set.
N/A
Parallel Sysplex® (XCF)
IXCHCCPL
See note 35.
3 is the default set by this check. See note 1.
For a discussion of considerations in allocating and managing couple data sets, see "Planning the Couple Data Sets" in z/OS MVS Setting Up a Sysplex.
For a discussion of formatting couple data sets, see "Format Utility for Couple Data Sets" in z/OS MVS Setting Up a Sysplex.
For the syntax of the SETXCF COUPLE command, see "SETXCF Couple Command" in z/OS MVS Setting Up a Sysplex.