CHECK(IBMXCF,XCF_CF_SYSPLEX_CONNECTIVITY) found an exception.
The number of coupling facilities in the CFRM active policy that have connectivity to all active systems in the sysplex is ctdcfs - the parameter requires at least mincfs. IXCH0908I and IXCH0909I have been placed in the message buffer to indicate the coupling facilities in the CFRM active policy and the systems that do not have connectivity to those coupling facilities.
See accompanying messages IXCH0908I and IXCH0909I for more information.
When running in a parallel sysplex environment, hardware redundancy should be provided for coupling facilities.
The system continues processing.
Report this problem to the system programmer.
Determine why the required number of coupling facilities are not available to all active systems in the sysplex, and take appropriate action. There might be a problem with a coupling facility definition in the active CFRM policy, a coupling facility, or a system's connectivity to a coupling facility.
See IXCH0908I and IXCH0909I in the message buffer that identify the active systems in the sysplex and the coupling facilities in the sysplex (with information about their connectivity to the active systems).
On systems that are not connected to a coupling facility, CHECK(IBMXCF,XCF_CF_CONNECTIVITY) provides additional information through message IXCH0448E.