When a system terminates, automatic restart management updates the state of elements owned by the terminated system to FAILED. When member cleanup for the terminated system completes, systems that are targeted to perform cross-system restart update the state of eligible elements to RESTARTING and perform cross-system restart processing.
When member cleanup for the terminated system does not complete within two minutes (120 seconds), systems targeted to perform cross-system restart update the state of eligible elements to RESTARTING and proceed to perform cross-system restart processing using the CLEANUP_TIMEOUT parameter to introduce additional delay, as necessary. The potential amount of additional delay is the amount of time specified by the CLEANUP_TIMEOUT value that is more than 2 minutes. When a CLEANUP_TIMEOUT value greater than 120 is specified (or defaulted to), and additional delay is introduced to wait for member cleanup processing to complete, message IXC815I is issued to the system log to record the delay in performing restart processing.
If the member cleanup does not occur within the time specified by the CLEANUP_TIMEOUT parameter, automatic restart management will proceed with processing the element for cross-system restart, and, if CLEANUP_TIMEOUT(120) is not being used, the system will issue IXC815I to the system log to record the time out.
The system continues processing.
None
None.
Cross System Coupling Facility (SCXCF)
IXCA3RST
2, Note 13
4