IXC373I
XCF/XES OPTIONAL FUNCTIONS action: function

Explanation

A COUPLExx parmlib member FUNCTIONS statement or a SETXCF FUNCTIONS command specified that one or more installation-controllable optional functions are to be enabled or disabled. This message reports the results of that request.Optional functions reported as NOT RECOGNIZED are not defined at the same release or service level of the issuing system. Possible reasons are as follows:
  • A COUPLExx parmlib member is shared between systems at different levels.
  • A SETXCF command is routed to systems at different levels.
  • An optional function name is misspelled.

Optional functions reported as NOT SUPPORTED FOR SETXCF COMMAND cannot be enabled and/or disabled dynamically using the SETXCF FUNCTIONS command. For example, the SETXCF FUNCTIONS command can be used to disable the CRITICALPAGING function but cannot be used to enable it.

In the message text:
action
One of the following actions:
ENABLED
The named optional functions have been enabled on the issuing system.
DISABLED
The named optional functions have been disabled on the issuing system.
NOT RECOGNIZED
The named optional functions are not defined at this release or maintenance level.
NOT SUPPORTED FOR SETXCF COMMAND
The SETXCF command cannot be used to take the specified action for the named optional functions.
function
The optional XES/XCF functions:
  • DUPLEXCF16
  • SYSSTATDETECT
  • USERINTERVAL
  • DUPLEXCFDIAG
  • CRITICALPAGING
  • Start of changeCFLCRMGMTEnd of change
  • Start of changeCOUPLINGTHININTEnd of change
For descriptions of the listed function names, see topic "The FUNCTIONS Statement" in z/OS MVS Setting Up a Sysplex.

System action

The system begins exploiting functions that have been enabled (subject to the establishment of any other prerequisites that are required for their use), or stops exploiting functions that have been disabled. The system takes no action with respect to unrecognized or unsupported functions.

Operator response

Take the following actions if any optional functions are reported as NOT RECOGNIZED:
  • If the message was issued in response to a SETXCF FUNCTIONS command, verify that the reported function names have been spelled correctly. If not, reissue the command if not. If all functions are spelled correctly, contact the system programmer.
  • If the message was issued in response to a COUPLExx FUNCTIONS statement, contact the system programmer.

System programmer response

If any optional functions are reported as NOT RECOGNIZED, verify their applicability to the system issuing the message. Correct the COUPLExx parmlib member if necessary. No action is required if the parmlib member or command was simply processed by a downlevel system.

If any optional functions are reported as NOT SUPPORTED FOR SETXCF COMMAND, update the COUPLExx parmlib member FUNCTIONS statement to enable or disable the functions on subsequent IPL.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCO1SCP, IXCI2PRM

Routing code

2, 10

Descriptor code

5, 12