IXC369I
THE SETXCF START | STOP MAINTMODE REQUEST FOR COUPLING FACILITY cfname WAS SUCCESSFUL | REJECTED: reason

Explanation

An operator entered a SETXCF START MAINTMODE or SETXCF STOP MAINTMODE command to start or stop the maintenance mode for a coupling facility. When a coupling facility is in maintenance mode, it is not eligible for structure allocation purposes. Furthermore, a coupling facility in maintenance mode is considered an undesirable location for the structure instances that it already contains, so that a rebuild, duplexing failover, or REALLOCATE process will tend to remove those structures from the coupling facility.

In the message text:
START
The request was to start maintenance mode.
STOP
The request was to stop maintenance mode.
cfname
The name of the coupling facility.
SUCCESSFUL
The request was successful.
REJECTED
The request was rejected.
reason
The reason why the request was rejected, which can be one of the following conditions:
COUPLE DATA SET FOR CFRM NOT AVAILABLE
The couple data set for CFRM is not available to this system.
POPULATECF REQUEST IN PROGRESS FOR THE COUPLING FACILITY
A PopulateCf rebuild request is in progress for the specified coupling facility. The coupling facility is not available for maintenance mode.
AN UNEXPECTED ERROR OCCURRED
An unexpected error occurred during processing of the maintenance mode request.
COUPLING FACILITY NOT DEFINED IN THE CFRM ACTIVE POLICY
The coupling facility is not defined in the CFRM active policy.

System action

When the command succeeds, the system has processed the request for the CF and either placed the coupling facility into the requested state, or found that the coupling facility was already in the requested state and therefore made no change.

When the command is rejected, the system ignores the request for the CF and makes no changes to the state of the CF.

Operator response

You can use the DISPLAY XCF,CF command to verify the state of the CF with respect to maintenance mode.

System programmer response

Provide directions to the operator as to the maintenance procedure being undertaken on the CF, and the proper use of the SETXCF START or STOP MAINTMODE command in carrying out that procedure.

Source

Cross System Coupling Facility (SCXCF)

Module

IXCO1SCP

Routing code

-

Descriptor code

5