IXG071D
REPLY R TO RETRY OR U TO USE THE CURRENT TIME AS THE CONSISTENCY TIME.

Explanation

Logger's attempt to obtain the consistency time from XRC session failed. Message IXG070I will have the return and reason code for the service failure. To perform the recovery operation, system logger needs a consistent time view from Extended Remote Copy (XRC). System logger uses the consistency time for managing converted DRXRC-type staging data set resources during log stream log data recovery.

System action

System logger stops initializing. The system logger address space has been made partially available mainly for display purposes. Following the response, the remaining system logger DRXRC conversion is attempted again or terminated. See the Operator Response for more details.

Operator response

Notify the system programmer, then respond to the message by selecting one of the following replies:
R
To request that system logger retry to obtain the consistency time from XRC. Use this response after taking the steps to remedy the reason for the failure identified in message IXG070I.
U
To request that system logger use the current time as the consistency time for managing converted DRXRC-type staging data set resources during log stream log data recovery. System logger will include all log stream log data in any converted DRXRC-type staging data set during the log stream recovery.

If you enter an incorrect reply, the system issues message IXG116I to notify the operator of the error. The system then reissues message IXG070D.

Regardless of the response to message IXG071D, conventional system level recovery of log stream connections will be performed for log streams that had failed connections.

System programmer response

Consult with the installation storage administrator and determine whether any log stream DRXRC-type staging data sets need to be managed for this DRMODE=YES IPL.

Use the D XCF,C,TYPE=LOGR and D LOGGER,C,SYSPLEX commands or use the IXCMIAPU DATA TYPE(LOGR) utility with the REPORT(YES) and LIST LOGSTREAM NAME(*) DETAIL options to help identify which log streams are using DRXRC-type staging data sets and need conversion for log data recovery use.

Use the necessary XRC commands (e.g. XQUERY) and services to identify the cause of the problem and make the necessary corrections. See z/OS MVS System Messages, Vol 1 (ABA-AOM) for an explanation of the ANTRQST service return and reason codes. For a description of XRC commands, see the z/OS DFSMS Advanced Copy Services manual. If RETCODE=7101 RSNCODE=3554068411 appears in the IXG070I message, then system logger converted the XRC return information because a zero time stamp was received.

Reply to message IXG071D to allow system logger initialization to continue.

If you are still unable to solve the problem, contact the IBM® Support Center and provide the retcode and rsncode from IXG070I.

User response

None.

Programmer response

None.

Source

System logger (SCLOG)

Module

IXGC4XRC

Routing code

1,2

Descriptor code

2