Explanation
The system initiated structure alter processing
has ended.
In the message text:
- strname
- The name of the structure.
- text1
- One of the following:
- ENDED. STRUCTURE FAILED.
- The structure alter request ended due to structure failure.
- ENDED. NO CONNECTIVITY TO STRUCTURE.
- The structure alter processing ended due to all systems which
are capable of performing structure alter processing having lost connectivity
to the coupling facility containing the structure.
- ENDED. REBUILD STARTED.
- The structure alter request ended due to a rebuild request for
the same structure.
- ENDED. STRUCTURE HAS BEEN DEALLOCATED.
- The structure alter request ended due to the deallocation of the
structure.
- ENDED. ALTER STOPPED BEFORE ANY CHANGES TO THE STRUCTURE OCCURRED.
- The structure alter processing ended because of a request to stop
alter processing. This request was processed before any coupling facility
operations with respect to the alter request could be performed. The
structure was not changed by the initial alter request.
- ENDED. COMPONENT ERROR.
- An unknown XES component error has occurred.
- text2
- One of the following:
-
- A duplexing rebuild is not in progress so no further information
is given.
- ALTER OF REBUILD-OLD STRUCTURE INSTANCE WAS ATTEMPTED.
- The structure alter request that ended was processing the Rebuild-Old
structure instance during a duplexing rebuild.
- ALTER OF REBUILD-NEW STRUCTURE INSTANCE WAS ATTEMPTED.
- The structure alter request that ended was processing the Rebuild-New
structure instance during a duplexing rebuild.
System action
System processing continues.
Source
Cross System Coupling Facility (SCXCF)
Module
Routing code
Descriptor code