IGW309E
UNABLE TO ESTABLISH INTER-SYSTEM LOCKING ENVIRONMENT, membername UNABLE TO JOIN groupname RC=return-code RSN=reason-code

Explanation

An error occurred when the system tried to join XCF. The message text displays the return and reason code.

In the message text:

membername
The name of the system within the sysplex.
groupname
The name of other members of the XCF group in the sysplex.
return-code
The return code
reason-code
The reason code

System action

The system will not allow use of PDSE. Until the inability to join the XCF group is resolved, this system cannot run with PDSE support. PDSE support is disabled because PDSE locking is not available.

Operator response

Notify the system programmer.

System programmer response

This is a warning message that the XCF configuration may be incorrect, or there is a problem with XCF.

Source

Storage management subsystem (SMS)