IKJ413I
TIME SHARING NOT SUPPORTED ON AN ASCB-BASED TCAM

Explanation

For a MODIFY jobname,TS=START command, jobname must identify a CVT-based TCAM. Either the MODIFY command specifies an incorrect jobname or TCAM was started as an ASCB-based TCAM, which does not support time sharing.

System action

The system does not start the time sharing option (TSO/E).

Operator response

If the MODIFY command specified the correct jobname, notify the system programmer. Otherwise, correct the jobname.

System programmer response

See the description of the BASED operand for the INTRO operand in ACF/TCAM Installation Guide.

Source

Time Sharing Option/Extensions (TSO/E)

Routing code

2,8

Descriptor code

5