IGF520A
VERIFICATION COMPLETE: REPLY 1 TERMINATE PAIR, AND SWAP | 2 SWITCH PAIR, AND SWAP | 3 CONTINUE SWAP | 4 TERMINATE SWAP

Explanation

The 'FROM' and 'TO' DASD devices were verified as a PPRC pair with the 'FROM' device being the source and the 'TO' device being the target. The operator is provided with three options for continuing processing or the option to terminate processing.

System action

Depends on the option selected by the operator.

Operator response

The operator must choose one of the four options.

Source

Dynamic device reconfiguration

Module

IECLDDRD