IWM055I
WLM LPAR CLUSTER STRUCTURE text

Explanation

This message is issued to provide status information for the WLM LPAR cluster structure as specified by text.

In the message, text can be:

NOT AVAILABLE, SYSTEM IN NON-LPAR MODE
WLM cannot connect to the structure because the system is running in LPAR mode. No WLM LPAR management support is available.
NOT AVAILABLE, SYSTEM IN XCF LOCAL MODE
WLM cannot connect to the structure because the system is running in XCF local mode. No WLM LPAR management support is available.
NOT AVAILABLE, SYSTEM IN MONOPLEX MODE
WLM cannot connect to the structure because the system is running in monoplex mode. No WLM LPAR management support is available.

System action

None

System programmer response

If WLM LPAR management support is required, the system must be reIPLed in LPAR mode and in XCF SYSPLEX mode.

Source

Workload manager (WLM)

Module

IWMC3TSK

Routing code

2,10

Descriptor code

5