IGW043I
text

Explanation

In the message text, text is one of the following:

  PDSE MONITOR IS HALTED
  Issue V SMS,PDSE RESTART to activate

or

  PDSE MONITOR IS INACTIVE

or

  PDSE MONITOR IS ACTIVE
  ++ DISPLAY MODE ACTIVE
  ++ DUMP NEXT MODE ACTIVE
  ++INVOCATION INTERVAL: iiiiii SECONDS
  ++SAMPLE DURATION: dddddddd SECONDS
The operation parameters for the PDSE monitor function may have changed. The new operational parameters are displayed, where:
HALTED
The state where the monitor has been stopped because of a previous error in the monitor.
INACTIVE
The state where the monitor is not running because the SMS parameter or the V SMS,PDSE,MONITOR,OFF command was issued.
ACTIVE
The state where the monitor is running normally.
++ Display Mode Active
Monitor displays message IGW031I for all possible error conditions discovered.
++ Dump Next Mode Active
Monitor takes an SVC dump for the next possible error condition discovered.
iiiiiiii
The number of seconds between monitor cycles.
dddddddd
The number of seconds an error condition must exist for it to be detected.
The parameters changed because:
  • The system IPLed.
  • The V SMS,PDSE,MONITOR command was issued.
  • The SET SMS=xx command was issued and the IGDSMSxx member contains the PDSE_MONITOR parameter.

Use the V SMS,PDSE,MONITOR command or the PDSE_MONITOR parameter of the IGDSMSxx parmlib member to change the operational parameters.

System action

None.

Operator response

None.

System programmer response

None; the message is informational.

Programmer response

None.

Source

Storage Management Subsystem (SMS)

Module

IGWLHAT1