IGW472I
DFSMS VSAM RLS REQUEST TO ENABLE TRANSACTIONAL VSAM INSTANCE TvsName IS REJECTED: TRANSACTIONAL VSAM MUST COLD START DUE TO I/O ERROR ON LOGSTREAM

Explanation

In the message text:
TvsName
The name of a DFSMStvs instance.

System action

The system continues processing.

Operator response

None

System programmer response

After the cold start, any data sets for which recovery was owed are most likely left in a damaged state and need to be recovered manually. If the data sets are forward recoverable, then their forward recovery logs might also be damaged. IBM® recommends that you manually recover the data sets (without using forward recovery), take backups of them and of any other data sets that use the forward recovery log, and then delete and redefine the forward recovery log.

Problem determination

None

Source

DFSMSdfp

Module

IGWSVTVS