IGW851I
date time SYSTEM LOGGER RETURNED AN ERROR DURING OPERATION IXGCONN CONNECT FOR LOG STREAM logstream. THE LOG STREAM IS A DASD-ONLY LOG WHICH IS NOT SUPPORTED BY THE CURRENT LEVEL OF SYSTEM LOGGER. SYSTEM LOGGER RETURN CODE rc REASON CODE rsnc

Explanation

DFSMStvs detected an error while attempting to connect to a log stream that is only for a direct access storage device (DASD). The system logger reported that DASD-only logs are not supported on this system.

In the message text:
date
The current date.
time
The current time.
logstream
The name of the log stream.
rc
The system logger return code.
rsnc
The system logger reason code.

System action

If the error occurred during access to either of the DFSMStvs system log streams (the undo or shunt log stream), both log streams are quiesced, as is DFSMStvs.

If the error occurred during access to either the log of logs or a forward recovery log, the log stream is made unavailable on this system.

Operator response

None

System programmer response

The return and reason codes shown are those returned by the system logger. You can interpret these return and reason codes by reviewing the description of errors for the appropriate system logger operation in z/OS MVS Programming: Assembler Services Reference ABE-HSP and z/OS MVS Programming: Assembler Services Reference IAR-XCT. Determine if the level of z/OS® is sufficient for running DFSMStvs.

Problem determination

None

Source

DFSMSdfp

Module

IGW9LMEC

Routing code

2,10

Descriptor code

-