DFSMStvs detected an error while attempting to connect to a log stream that is only for a direct access storage device (DASD). The system logger reported that DASD-only logs are not supported on this system.
If the error occurred during access to either of the DFSMStvs system log streams (the undo or shunt log stream), both log streams are quiesced, as is DFSMStvs.
If the error occurred during access to either the log of logs or a forward recovery log, the log stream is made unavailable on this system.
None
The return and reason codes shown are those returned by the system logger. You can interpret these return and reason codes by reviewing the description of errors for the appropriate system logger operation in z/OS MVS Programming: Assembler Services Reference ABE-HSP and z/OS MVS Programming: Assembler Services Reference IAR-XCT. Determine if the level of z/OS® is sufficient for running DFSMStvs.
None
DFSMSdfp
IGW9LMEC
2,10
-