IGW839I
date time AN ERROR OCCURRED DURING SYSTEM LOGGER OPERATION {IXGCONN | IXGWRITE | IXGBRWSE | IXGDELET} {CONNECT | DISCONNECT | START | READCURSOR | READBLOCK | END | ALL | RANGE} FOR {SYSTEM | FORWARD RECOVERY} LOG STREAM logstream. SYSTEM LOGGER RETURN CODE rc REASON CODE rsnc

Explanation

DFSMStvs called the system logger to access a log, and the system logger returned an error condition. The message identifies the system logger operation that returned the error condition and shows the return and reason codes that the system logger returns. Other DFSMStvs messages might follow message IGW839I, especially if the log stream is a DFSMStvs system log.

This situation can occur under one of the following conditions:
  • DFSMStvs calls the system logger using an obsolete log stream connection token.
  • Either a crash or a user request causes the system logger to be restarted.
In the message text:
date
The current date.
time
The current time.
logstream
The name of the log stream.
rc
The system logger return code.
rsnc
The system logger reason code.

System action

The system action depends on the nature of the error that the system logger returns.

Operator response

None

System programmer response

If the system logger was recently restarted, shut down DFSMStvs and restart it. Otherwise, use the system logger return and reason codes to diagnose the problem. You can interpret these return and reason codes by reviewing the descriptions of errors for the appropriate system logger operation in z/OS MVS Programming: Assembler Services Reference ABE-HSP and z/OS MVS Programming: Assembler Services Reference IAR-XCT.

Problem determination

None

Source

DFSMSdfp

Module

IGW9LMEC

Routing code

2,10

Descriptor code

-