System Management Facilities (SMF) could not locate an installation exit routine.
SMF processing continues but bypasses the installation exit.
Determine if the routine is properly link edited into SYS1.LPALIB. If the routine has been replaced since the system was installed, check the linkage editor output for the most recent change. If the correct version of the routine is in SYS1.LPALIB, restart the system with a cold start (CLPA) to make the routine available.
If the routine has not been replaced since the system was installed, check the output from the install process to be sure the routine was correctly installed.
System Management Facilities (SMF)
IEEMB821
2,10
5