IEE730I
DUPLICATE xxxx SUBSYSTEM NOT INITIALIZED

Explanation

Subsystem name xxxx, identified in an IEFSSNxx member of SYS1.PARMLIB, is a duplicate of an existing subsystem name.

System action

The system does not build a subsystem communication vector table (SSVCT) for the duplicate subsystem name.

If the system found the duplicate name in SYS1.PARMLIB, the system ignores the initialization routine specified with the duplicate subsystem name.

Operator response

Report this message to the system programmer.

System programmer response

Determine why subsystem xxxx was named more than once.

If subsystem xxxx is not properly initialized, and is essential for system processing, correct the error and reIPL.

Obtain the JCL for the job.

If you use SMP/E to make all changes to the system, obtain a full list of the current maintenance from the SMP/E control data set (CDS).

If the problem recurs and if the program is not in error, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center.

Source

JES2

Module

IEFJSBLD

Routing code

2,10

Descriptor code

4