A reconfiguration request asked that the system reconfigure storage offline. The system tried to vary the storage offline, but it could not complete the requested reconfiguration; all of the storage has not gone offline.
The system continues to try to reconfigure the requested storage offline until you reply to this message.
Before replying to the message, you can enter DISPLAY M=STOR to help identify tasks that are preventing the completion of the CONFIG STOR command. Based on the information displayed, you can cancel tasks or wait for tasks to complete.
If you enter anything by C, the system issues this message again.
If the request does not complete successfully, notify the system programmer.
Work with the operator to determine what, if any, storage has gone offline and what to do to complete the request.
Reconfiguration
IEEVSTGL
-
7