Explanation
A SET command requested that the system use parameters
specified in a parmlib member. While processing the parmlib member,
the system detected incorrect parameters in the parmlib member.
In
the message text:
- prm
- The incorrect parameter.
- memberxx
- The parmlib member in which incorrect parameters were found.
System action
The system continues processing, using the existing
parmlib parameters. The system may issue the following messages, which
contain detailed information about the error, to the system log:
- Message IRA300I
- Message IRA301I
- Message IRA302I
- Message IRA303I
- Message IRA304I
- Message IRA305I
Operator response
Contact the system programmer.
System programmer response
Do the following:
- See the explanation for any messages issued to the system log.
- Check and correct the syntax of the parameters in the parmlib
member. Use the messages in the system log to help diagnose the error.
- If the problem cannot be resolved, search problem reporting data
bases for a fix for the problem. If no fix exists, contact the IBM® Support
Center.
Source
Module
Routing code
Descriptor code