IEB841I
INVALID RETURN CODE FROM routine, TOTALING EXITS DISCONTINUED

Explanation

The return code passed to IEBUPDTE by the user totaling routine during a totaling exit was not valid. That is, the return code was not 0, 4, 8, or 16.

In the message text:
routine
The user totaling routine.

System action

Totaling exits are discontinued, but processing continues. The return code is 0.

System programmer response

If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the JCL and the program listing for the job. Have the exit routine listings available.

Programmer response

Probable user error. Check the user routine to make sure that a valid return code was passed to the utility program. Resubmit the job.

Source

DFSMSdfp